Honeywell CHRONOTHERM III T8611M Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Panneau de contrôle Honeywell CHRONOTHERM III T8611M. Honeywell CHRONOTHERM III T8611M User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 32
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
1 68-0076—1
CONTENTS
Specifications ................................................. 2
Ordering Information ..................................... 2
Selection/Application ..................................... 5
Installation ................................................... 12
Checkout....................................................... 18
Programming The Thermostat ..................... 20
Operating The Thermostat ........................... 25
Operation ..................................................... 27
Troubleshooting ........................................... 29
Glossary ....................................................... 30
Table of Contents ......................................... 32
T8611M
(7-Day Programming)
Chronotherm III™
Heat Pump Thermostats
The T8611M Chronotherm III Programmable
Thermostat provides automatic control of multi-
stage heat pump systems and offers users the
highest standard of comfort and convenience
available with energy savings.
Full seven-day program capability; different sched-
ules may be selected for every day.
Can be programmed in hand (with batteries in-
stalled) or on the wall to provide up to four tem-
perature periods per day.
Large digital clock (liquid crystal display) indi-
cates continuous time-of-day, day-of-week, cur-
rent period and room temperature.
Adaptive Intelligent Recovery™ brings room tem-
perature to programmed temperature at program-
med time, maximizing comfort and energy sav-
ings.
Temperature control program maintains tempera-
ture within 1° F of setpoint.
Temporary program override available by using—
WARMER and COOLER keys.
SKIP next period key.
CHANGE to last period key.
HOLD TEMP key provided for indefinite program
override (vacation/holiday).
Installer self-test with time delay override saves
installation time.
SYSTEM light-emitting diode (LED) on thermo-
stat indicates system is energized.
AUX. HT., EM. HT., CHECK LEDs available on
select models.
Automatic heat/cool changeover.
Batteries included provide power to maintain clock
and memory during power failures.
Switching subbase with wiring terminals included.
Powered directly from control transformer.
Model available with separate sensor for remote
temperature sensing.
C. H. • Rev. 10-92 • ©Honeywell Inc. 1992 • Form Number 68-0076—1
Vue de la page 0
1 2 3 4 5 6 ... 31 32

Résumé du contenu

Page 1 - Heat Pump Thermostats

1 68-0076—1CONTENTSSpecifications ... 2Ordering Information ... 2Selec

Page 2 - Specifications

10TABLE 3—T8611 GUIDE FOR REPLACING POPULAR T874 AND T872 THERMOSTATS,BY EQUIPMENT MANUFACTURER (Continued).(NOTE: Also see form 70-6627, Heat Pump Th

Page 3 - SPECIFICATIONS

11 68-0076—1TABLE 3—T8611 GUIDE FOR REPLACING POPULAR T874 AND T872 THERMOSTATS,BY EQUIPMENT MANUFACTURER (Continued).(NOTE: Also see form 70-6627, He

Page 4

12InstallationCOMPATIBILITYThe T8611 Thermostats will replace most heat pumpsystem thermostats. As long as ac power is continuouslyavailable to the th

Page 5 - Selection/Application

13 68-0076—1Fig. 4—Removing thermostat from subbase.The subbase mounts directly onto the wall with thescrews and anchors included. Instead, the subbas

Page 6

14STAGE 2 COMPRESSOR CONTACTORPOWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED.POSSIBLE CHECK LED CIRCUITS:SOME OLDER HEAT

Page 7

15 68-0076—1Fig. 7—Restrict wiring to recessed area surrounding terminals.T8611MINSTALLATIONDENOTES THERMOSTAT TO SUBBASE INTERCONNECT.APPLICABLE ONLY

Page 8

16Fig. 8—T8611M Thermostat with EM.HT.-HEAT-OFF-AUTO-COOL system and ON-AUTO fan switching;EM.HT., CHECK, and AUX. HT. LEDS. Applied to 3-stage heat/2

Page 9

17 68-0076—1EM.HT. and CHECK LEDs. Applies to 2-stageheat/2-stage cool system in which both heatingstages are compressorized.Fig.10—T8611M Thermostat

Page 10

18Fig. 13—Mounting thermostat on subbase.Checkout!CAUTIONDuring cold weather, some heat pumps will re-quire that crankcase heater be energized several

Page 11

19 68-0076—1System Press Look For This ResponseSwitch This KeyPosition Key Down Key ReleasedOFF 03 Blank07 Blank15 BlankCOOL or 15 1st stage cooling,

Page 12 - Installation

2T8611MSPECIFICATIONS • ORDERING INFORMATIONSpecificationsOrdering InformationWhen purchasing replacement and modernization products from your TRADELI

Page 13

20M5346Third System Switch SensorDigit Position Location0 COOL, AUTO or OFF Local1 HEAT or EM.HT. Local4 COOL, AUTO or COOL Remote5 HEAT or EM. HT. Re

Page 14 - INSTALLATION

21 68-0076—1Press and hold until the display shows thetime that the temperature should be at thecomfort setting.Press and hold until the display shows

Page 15 - 15 68-0076—1

22Press and release. The display showsNIGHT and the preprogrammed time andtemp-erature.Press and hold until the display shows thetime to start the ene

Page 16

23 68-0076—1STEP 3COPYING THE PROGRAM TOTHE DESIRED DAYSIt is possible to copy the program forone day to any other day or combina-tion of days. The ne

Page 17 - DAY/TIME

24Press and release so COOL shows on thedisplay.Press and release the PERIOD key to stepthrough the time periods, and use theWARMER/COOLER keys to set

Page 18 - Checkout

25 68-0076—1Then set the system switch. (contin-ued)AUTO (select models only): The ther-mostat controls either the heating or cool-ing system, dependi

Page 19

26REPROGRAMMING THETHERMOSTATIf schedule changes or a different tem-perature is desired, update any settingwithout affecting the rest of the pro-gram.

Page 20 - Programming The Thermostat

27 68-0076—1Press and release to return to normaloperation.CHECKING THE PROGRAMTIMES AND TEMPERATURESIf desired, check all the stored settingswithout

Page 21

28the auxiliary heat even when the T8611 is calling for it.(Balance point is the outdoor temperature below which theheat pump must call on auxiliary h

Page 22

29 68-0076—1TroubleshootingHEAT PUMP OR AUXILIARY HEAT WON'T OPERATENO ac POWER TO THERMOSTATCHECK POWER TO HEAT PUMP OR AUXILIARY HEATING SYSTE

Page 23

3 68-0076—1T8611MSPECIFICATIONSFig. 1—T8611 Subbase mounting dimensions in in. [mm].4 [121]343 [83]5167 [179]1 [46]13165 [135]516M5181A

Page 24

30conditioning equipment to return the building from theenergy saving temperature to the comfort temperature.The thermostat starts the recovery period

Page 25 - Operating The Thermostat

31 68-0076—1T8611MTABLE OF CONTENTSTable of ContentsPageSpecifications ...

Page 26

32Home and Building Control Home and Building Control Helping You Control Your WorldHoneywell Inc. Honeywell Limited—Honeywell Limitée1985 Douglas Dri

Page 27 - Operation

4T8611MSPECIFICATIONSFig. 3—Typical thermostat keypad.SYSTEMRUNPROGRAMPERIODTIMETEMPERATUREPRESENTSETTINGSKIPNEXTPERIODCHANGETO LASTPERIODSETPRESENTDA

Page 28

5 68-0076—1T8611MSELECTION/APPLICATIONSelection/ApplicationThe T8611 Thermostat uses the latest microelectronicdesign and control technology to provid

Page 29 - Troubleshooting

6Table 2 lists features and wiring terminal functions of the TRADELINE T8611M thermostat.TABLE 2—T8611M FEATURES AND TERMINALS.T8611MFEATURESCOMMENTSH

Page 30 - Glossary

7 68-0076—1(continued)TABLE 3—T8611 GUIDE FOR REPLACING POPULAR T874 AND T872 THERMOSTATS,BY EQUIPMENT MANUFACTURER.(NOTE: Also see form 70-6627, Heat

Page 31 - Table of Contents

8(continued)TABLE 3—T8611 GUIDE FOR REPLACING POPULAR T874 AND T872 THERMOSTATS,BY EQUIPMENT MANUFACTURER (Continued).(NOTE: Also see form 70-6627, He

Page 32 - Printed in U.S.A