Honeywell Q539F Manuel d'utilisateur Page 1

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Panneau de contrôle Honeywell Q539F. Honeywell Q539F User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 12
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
Honeywell
THERMOSTAT
SUBBASES
THE Q539 SUBBASES PROVIDE COOLING ANTICI
PATORS. WIRING TERMINALS. AND MOUNTING
BASES FOR T87F THERMOSTATS. MOST ALSO
PROVIDE SYSTEM AND FAN SWITCHING FOR
HEATING. COOLING. AND HEATING-COOLING
THERMOSTATS.
Screw terminals for electrical connections are letter-
coded for quick, accurate installation.
Shunt type carbon heater provides cooling anticipa
tion for close temperature control.
Guide posts assure mounting and leveling necessary
to maintain thermostat calibration.
Fan and system switch levers (available on most
models) located at top edge for convenient control.
Indicator LED available on most models.
Mount directly on wall or on standard outlet box with
accessory wallplate. i
Q539P with indicator LED for oil primary systems
(HEAT-only).
Q539A,B,C,F,
D.T.
Rev. 10-89
Form Number 60-2246—4
© Honeywell Inc. 1989
Vue de la page 0
1 2 3 4 5 6 ... 11 12

Résumé du contenu

Page 1 - Honeywell

HoneywellTHERMOSTATSUBBASESTHE Q539 SUBBASES PROVIDE COOLING ANTICIPATORS. WIRING TERMINALS. AND MOUNTING BASES FOR T87F THERMOSTATS. MO

Page 2 - ORDERING INFORMATION

OPERATIONThe Q539 Subbase provides cooling anticipation, wiring terminals, mounting base, and system and fan switching for the T87F Thermostat

Page 3

NOTES—1160-2246—4

Page 4 - INSTALLATION

Honeywell Inc.1885 Douglas Drive N.International Sales Offices in all principal cities of the world. Manufacturing in Australia, Canada, Finland, Fran

Page 5

SPECIFICATIONSIMPORTANTTHE SPECIFICATIONS GIVEN IN THIS PUBLICATION DO NOT INCLUDE NORMAL MANUFACTURING TOLERANCES. THEREFORE, THIS UNI

Page 6 - <i) I

TABLE 1—MODEL SPECIFICATIONSMODEL AND DESCRIPTIONSYSTEM SWITCHING (dpst and dp3t)FANSWITCHING(spdt)SUBBASE TERMINALS WIRINGDIAGRAMR W Y BGo X p zRc R»

Page 7 - 7 60-2246-4

Table 1 (continued)MODEL AND DESCRIPTIONSYSTEM SWITCHING (dpst and dp3t)FANSWITCHING(spdt)SUBBASE TERMINALSWIRINGDIAGRAMR W Y B GO X p zRc R-Q539J1022

Page 8

they can be pushed back into the wall later.2. In new installations, run wiring (if necessary) to the subbase location.3. Connect the wires to

Page 9 - CHECKOUT

Q539An'87FHEATING DAMPER MOTOR (IF USED)WITCH_C “<i) IA ^T-0^1COOLING DAMPER MOTOR (IF USED)“1“AA X TERMINAL IS USED ON 0539 MODELS WITH FACTO

Page 10 - OPERATION

-EXAMPLE;FOR Rc TO Rh JUMPER. STRIP WIRE END LONG ENOUGH TO JOIN BOTH TERMINALS.FIG. 5-JUMPER "R^" AND "R„" TERMINALS FOR CO

Page 11 - 60-2246—4

PROTECTION AS REQUIRED.És^JUMPER FOR AUTO FAN IN ELECTRIC HEAT APPLICATIONS. IF JUMPER IS USED. MEASURE COMBINED “HEAT RELAY" AND "FAN RELAY

Page 12 - QUALITY IS KEY

Q539P/T87FAPOWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOADPROTECTION AS REQUIRED.M1029AMOLDED POST (2)VERTICAL PLUMP I LINEOPENING FOR THERMOSTAT

Modèles reliés Q539H | Q539P | Q539C | Q539B | Q539J | Q539G |

Commentaires sur ces manuels