Setup functions Settings & Options (factory default in bold)
0540 Program periods
4 4 program periods (Wake, Leave, Return, Sleep)
2 2programperiods(Wake,Sleep)
0580 Compressor
protection
5 5 minute compressor off time
[Other options: 0, 1, 2, 3 or 4-minute off time]
0600 Heat temperature
range stop
90 Max. heat temperature setting is 9F (32°C)
[Other options: 40-89°F (4°C to 32°C)]
0610 Cool temperature
range stop
50 Min. cool temperature setting is 50°F (10°C)
[Other options: 51-99°F (11°C to 37°C)]
0615 Energy Saving
Heat Setpoint
65 65°F (18.C)
40-90°F (4.5°C to 32°C)
0616 Energy Saving
Cooling Setpoint
78 78°F (25.5°C)
50-99°F (10°C to 37°C)
0640 Clock format
12 12-hour time (i.e., “3:30 pm)
24 24-hour time (i.e., “15:30)
0650 Extended fan
timer (heat)
0 Off
90 Fan runs for 90 seconds after call for heat ends
[Other options: 30, 60, 120]
0660 Extended fan
timer (cool)
0 Off
90 Fan runs for 90 seconds after call for cooling ends
[Other options: 30, 60, 120]
0670 Keypad lock
0 Keypad unlocked (fully functional)
1 Partially locked (access to temperature settings only)
2 Fully locked
0680 Heat temperature
control
2 Standard temperature control (recommended)
1 Choose if room is warmer than set temperature
3 Choose if room does not reach set temperature
0690 Cool temperature
control
2 Standard temperature control (recommended)
1 Choose if room is cooler than set temperature
3 Choose if room does not reach set temperature
0700 Temperature
display offset
0 Thermostat displays actual room temperature
[Other options: -3, -2, -1, 1, 2, 3°F offset (-1.5°C to 1.5°C)]
0710 Reset
0 No reset
1 Resetinstalleroptions,theZ-WaveRadiomodule,&program-
ming schedule to factory default (only date and time settings
are retained)
rf10 Z-Wave Network
Connection
0 Remove
1 Add
rf20 Z-Wave Node
Connection
0 Idle
1 Send Node
Installer setup
69-2486-06_C.indd 9 9/8/11 11:47 AM