INSTALLATION INSTRUCTIONS
62-0278-07
TB6575/TB8575 SuitePRO™
Digital Fan Coil Thermostats
PRODUCT DESCRIPTION
The SuitePRO™ is a family of Digital Fan Coil
thermostats for residential and commercial applications
such as hotels, condominiums, school classrooms, etc.
Four models are available for your application:
TB6575A1000:
2-pipe or 4-pipe with seasonal/manual/
automatic heat/cool changeover; 120/240 Vac.
TB6575B1000: 2-pipe only with seasonal or manual
heat/cool changeover; 120/240 Vac.
TB6575C1000: 2-pipe or 4-pipe with seasonal/manual/
automatic
heat/cool changeover; 120/240/277 Vac.
TB8575A1000: 2-pipe or 4-pipe with seasonal heat/
cool changeover; 24Vac.
All four models are suitable for multiple applications.
Changes in output wiring and external links between
wiring terminals allow you to configure the thermostat for
the appropriate application.
The applications that are available are:
Heating or Cooling only
Two pipes: Heat or Cool with Manual Changeover
Two pipes: Heat or Cool with Seasonal Changeover
(requires optional pipe sensor)
Two pipes: Heat or Cool with Auxiliary Heat and
Manual or Seasonal Changeover (requires optional
pipe sensor)
Four pipes: Mixed Manual and Auto Changeover
Four pipes: Manual Changeover
Four pipes: Auto Changeover
The fan is controlled from the thermostat. The Low,
Medium, High, or Auto fan settings are easily made with
a press of a key.
Valves and auxiliary electric heaters can be controlled using
a relay or contactor controlled by the system switch.
FEATURES
Simple, intuitive user interface.
Pre-installed lead wires for fast installation
(TB6575A, TB6575B and TB6575C models only)
Backlight display permits easy viewing in any
light.
Four buttons allow manual control of system
operation, fan speed, and temperature setpoint
adjustment.
Digital display of ambient temperature, setpoint,
heating or cooling mode, fan status, and remote
setback
Proportional plus Integral (P+I) control algorithm
for precision temperature regulation.
Single Setpoint and Heat/Cool setpoint methods
for 4-pipe auto changeover.
Adjustable maximum heating and minimum
cooling setpoint limits using range stops.
EEPROM permanently retains user settings,
including setpoints, during power loss (no
batteries required).
Selectable °C or °F display via Setup button on
thermostat.
Displayable pipe sensor temperature readout to
aid in troubleshooting.
Selectable to allow the fan motor to always begin
on high speed to ensure sufficient torque at
startup.
Option to wire a remote indoor temperature
sensor.
Freeze protect algorithm turns on heat when
needed.
Economy Setback options via dry contact or
Activity Sensing
Advanced fan control with VersaSpeed(TM) fan
ramp algorithm and Auto Fan Reset
Vue de la page 0
1 2 3 4 5 6 ... 19 20

Résumé du contenu

Page 1 - Digital Fan Coil Thermostats

INSTALLATION INSTRUCTIONS62-0278-07TB6575/TB8575 SuitePRO™ Digital Fan Coil ThermostatsPRODUCT DESCRIPTIONThe SuitePRO™ is a family of Digital Fan Coi

Page 2 - SPECIFICATIONS

TB6575/TB8575 SUITEPRO™ DIGITAL FAN COIL THERMOSTATS62-0278—07 10Fig. 21. Removing the thermostat.SETUPThe thermostat provides an LCD display, two but

Page 3 - INSTALLATION

TB6575/TB8575 SUITEPRO™ DIGITAL FAN COIL THERMOSTATS11 62-0278—07 Fig. 24. Installer Setup (IS) mode screen.M27585SetupTable 4. Installer Setup (IS) C

Page 4 - Terminal Wiring

TB6575/TB8575 SUITEPRO™ DIGITAL FAN COIL THERMOSTATS62-0278—07 126 Pipe Sensor Threshold for Cooling50 to 72Range is 50°F to 72°F. Default is 60°F. Ch

Page 5 - 5 62-0278—07

TB6575/TB8575 SUITEPRO™ DIGITAL FAN COIL THERMOSTATS13 62-0278—07Installer Test (IT) ModeTo enter Installer Test Mode:• Press and hold both the Up arr

Page 6 - Accessory Wiring

TB6575/TB8575 SUITEPRO™ DIGITAL FAN COIL THERMOSTATS62-0278—07 14Table 5 provides the Test codes (IT codes) and values. To enter the IT codes:1. Press

Page 7 - Thermostat Wiring Diagrams

TB6575/TB8575 SUITEPRO™ DIGITAL FAN COIL THERMOSTATS15 62-0278—07BUTTON PRESS SETBACK (IS CODE #19-5)The default remote setback option is for economy

Page 8 - 62-0278—07 8

TB6575/TB8575 SUITEPRO™ DIGITAL FAN COIL THERMOSTATS62-0278—07 162 Pipes with Auto ChangeoverFor this application the system switch only provides &quo

Page 9 - Removing the Thermostat

TB6575/TB8575 SUITEPRO™ DIGITAL FAN COIL THERMOSTATS17 62-0278—07Fig. 29. 4 Pipe Auto Changeover with Single Setpoint and Switching PointsHeat/Cool Se

Page 10 - Installer Setup (IS) Mode

TB6575/TB8575 SUITEPRO™ DIGITAL FAN COIL THERMOSTATS62-0278—07 18Both the heating and cooling equipment are running at the same time. Incorrect System

Page 11 - 11 62-0278—07

TB6575/TB8575 SUITEPRO™ DIGITAL FAN COIL THERMOSTATS19 62-0278—07LIMITED TWO-YEAR WARRANTYHoneywell warrants this product, excluding battery, to be fr

Page 12 - 62-0278—07 12

TB6575/TB8575 SUITEPRO™ DIGITAL FAN COIL THERMOSTATS62-0278—07 2SPECIFICATIONSSupply Voltages:TB6575A1000 and TB6575B1000:• 120 Vac ±10% at 50/60Hz• 2

Page 13 - Installer Test (IT) Mode

TB6575/TB8575 SUITEPRO™ DIGITAL FAN COIL THERMOSTATSAutomation and Control SolutionsHoneywell International Inc.1985 Douglas Drive NorthGolden Valley,

Page 14 - OPERATION

TB6575/TB8575 SUITEPRO™ DIGITAL FAN COIL THERMOSTATS3 62-0278—07Fig. 1. Dimensions in inches (mm).INSTALLATIONWhen Installing this Product…1. Read the

Page 15 - Fan Modes

TB6575/TB8575 SUITEPRO™ DIGITAL FAN COIL THERMOSTATS62-0278—07 4(1) Attach the supply wires directly to the termi-nals on the sub-base. See Table 3 on

Page 16 - 62-0278—07 16

TB6575/TB8575 SUITEPRO™ DIGITAL FAN COIL THERMOSTATS5 62-0278—07• Ps: Pipe sensor (optional)• R: 24 Vac power• Rs: Remote sensor (optional)• SB: Remot

Page 17 - HEATING SETPOINT

TB6575/TB8575 SUITEPRO™ DIGITAL FAN COIL THERMOSTATS62-0278—07 6Accessory WiringRemote Pipe Sensor WiringThe remote pipe sensor is used for 2 pipes au

Page 18 - 62-0278—07 18

TB6575/TB8575 SUITEPRO™ DIGITAL FAN COIL THERMOSTATS7 62-0278—07Thermostat Wiring DiagramsThe figures in this section illustrate typical wiring for:•

Page 19 - 19 62-0278—07

TB6575/TB8575 SUITEPRO™ DIGITAL FAN COIL THERMOSTATS62-0278—07 8.Fig. 13. Wiring diagram when missing a wire for electromechanical retrofit (120/240/2

Page 20 - Printed in United States

TB6575/TB8575 SUITEPRO™ DIGITAL FAN COIL THERMOSTATS9 62-0278—07Fig. 17. Two pipes (Heat or Cool) auto changeover wiring diagram (24 Vac shown).Fig. 1

Commentaires sur ces manuels

Pas de commentaire